Related Articles
Launcher Is Cycling Elevation Constantly
Possible Cause#1 Possible bad PCM/PCR Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from PCR-including ...
No Fire In Training Mode, No Launcher Elevation, CP and Laser On, Pressure Good
Possible Cause#1 Bad CB, PCM/PCR, or 12V connection to PCM/PCR Solution Set#1 Check for 12V going into PCM/PCR. If no 12V check fuse for PCM/PCR. If 12V present proceed to next step Check for 12V at orange wire on 4 Pin connector. If no 12V replace ...
Heaters Not Working
Possible Cause#1 Damaged heating element Solution Set#1 Inspect heaters for damage Replace launcher If applicable replace heaters (check serial number in serial tracking for QR heaters) Possible Cause#2 Door heaters failing to heat or heat ...
When Pressing "ON" System Starts Powering Up Sequence But Cycle Stops Abruptly
Possible Cause#1 Bad car battery leading to a low voltage results in failure to power StarChase system Car alternator needs work/replaced Solution Set#1 Check to see if "ON" and "Down Arrow" buttons are illuminated
System Shutting Off Randomly After Armed To Fire
Possible Cause#1 Bad car battery leading to a low voltage results in failure to power StarChase system Solution Set#1 Verify connections Check Fuse Holders Ensure vehicle had enough time to charge battery post installation