Lack Of Pressure When Firing
Possible Cause#1
Malfunctioning pressure switch
Solution Set#1
Replace pressure switch
Blow-by from launcher
Solution Set#2
Replace launcher
Related Articles
DS Valve Not Firing
Possible Cause#1 DS will not fire Solution Set#1 In training mode PS will always fire first Fired PS in training mode then system timed out Ensure system is fired for both barrels before system times out Solution Set#2 In Normal mode system will fire ...
No Fire In Training Mode, No Launcher Elevation, CP and Laser On, Pressure Good
Possible Cause#1 Bad CB, PCM/PCR, or 12V connection to PCM/PCR Solution Set#1 Check for 12V going into PCM/PCR. If no 12V check fuse for PCM/PCR. If 12V present proceed to next step Check for 12V at orange wire on 4 Pin connector. If no 12V replace ...
Launcher Air Leak
Possible Cause#1 Faulty Pressure Switch Solution Set#1 Replace pressure switch/valve assembly Possible Cause#2 Hose malfunction Solution Set#2 Fitting at the launcher not seated correctly
Rounds Not Deploying Properly
Possible Cause#1 Screws loose on Door Cover Solution Set#1 Check and tighten screws on Door Possible Cause#2 Round flips after being deployed Solution Set#2 Round hit door during deployment Officer did "hard braking" during deployment ...
When Pressing "ON" System Starts Powering Up Sequence But Cycle Stops Abruptly
Possible Cause#1 Bad car battery leading to a low voltage results in failure to power StarChase system Car alternator needs work/replaced Solution Set#1 Check to see if "ON" and "Down Arrow" buttons are illuminated