Laser Alignment Off
Possible Cause#1 Solution Set#1 Complete launcher aiming procedure
No Compressor Or Launcher Control, Laser works
Possible Cause#1 Defective PCM/PCR, fuse, wiring Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from ...
Launcher Fails To Arm; No Laser With System On
Possible Cause#1 Control Panel Connections Solution Set#1 Verify Ignition power Verify 12V and ground connections Ensure Can-Bus Harness is connected ...
No Fire In Training Mode, No Launcher Elevation, CP and Laser On, Pressure Good
Possible Cause#1 Bad CB, PCM/PCR, or 12V connection to PCM/PCR Solution Set#1 Check for 12V going into PCM/PCR. If no 12V check fuse for PCM/PCR. If 12V present proceed to next step Check for 12V at orange wire on 4 Pin connector. If no 12V replace ...
Launcher Is Cycling Elevation Constantly
Possible Cause#1 Possible bad PCM/PCR Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from PCR-including ...