Launcher Fails To Arm; No Laser With System On
Possible Cause#1
Control Panel Connections
Solution Set#1
- Verify Ignition power
- Verify 12V and ground connections
- Ensure Can-Bus Harness is connected
________________________________________________________________________________________________________________________________________________________
Possible Cause#2
No power from PCM/PCR
Solution Set#2
Check all power fuses
Power up system put in training mode
Check for movement of the launcher and/or compressor operation
Check all connections and wiring
Check power from PCR-including disconnecting grey Delphi and checking power at the connector
Orange Wire - 12VDC
Black Wire - Ground
Red Wire - 5VDC
Replace PCM/PCR
______________________________________________________________________________________________________________________________________________________________
Possible Cause#3
Defective Computer Box
Solution Set#3
"Plug in" new Computer Box to test
Related Articles
Laser Aim Off
Possible Cause#1 Lost memory in stepper Solution Set#1 Put system in training mode and hard park it See StarChase V3.0 Launcher Park Reset Instructions Possible Cause#2 Laser needs re-aimed Solution Set#2 Follow laser aiming instructions See ...
No Compressor Or Launcher Control, Laser works
Possible Cause#1 Defective PCM/PCR, fuse, wiring Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from ...
Rounds Not Reporting In Launcher
Possible Cause#1 Not properly seated Solution Set#1 Confirm that rounds are seated properly Arm system and check to see if rounds come up on mapping Replace rounds Possible Cause#2 Battery dead Solution Set#2 Replace round Possible Cause#3 No ...
Launcher Is Cycling Elevation Constantly
Possible Cause#1 Possible bad PCM/PCR Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from PCR-including ...
No Fire In Training Mode, No Launcher Elevation, CP and Laser On, Pressure Good
Possible Cause#1 Bad CB, PCM/PCR, or 12V connection to PCM/PCR Solution Set#1 Check for 12V going into PCM/PCR. If no 12V check fuse for PCM/PCR. If 12V present proceed to next step Check for 12V at orange wire on 4 Pin connector. If no 12V replace ...