System Locked-No Elevation, No Laser
Possible Cause#1
No power to Computer Box
Solution Set#1
- Check fuse for PCM/PCR, replace if bad
Check for movement of the launcher and/or compressor operation
Check all connections and wiring
Check power from PCM/PCR-including disconnecting grey Delphi and checking power at the connector
Orange Wire - 12VDC
Black Wire - Ground
Red Wire - 5VDC
Replace PCM/PCR
Possible Cause#2
Water intrusion to Computer Box
Solution Set#2
Replace Computer Box
Related Articles
Laser Aim Off
Possible Cause#1 Lost memory in stepper Solution Set#1 Put system in training mode and hard park it See StarChase V3.0 Launcher Park Reset Instructions Possible Cause#2 Laser needs re-aimed Solution Set#2 Follow laser aiming instructions See ...
Launcher Is Cycling Elevation Constantly
Possible Cause#1 Possible bad PCM/PCR Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from PCR-including ...
Launcher Fails To Arm; No Laser With System On
Possible Cause#1 Control Panel Connections Solution Set#1 Verify Ignition power Verify 12V and ground connections Ensure Can-Bus Harness is connected ...
Intermittent Elevation
Possible Cause#1 Console was wired backwards/incorrectly Solution Set#1 Failed to hard park when in training mode (all connections flowed with the movement of the Launcher so nothing was preventing it from moving) System blew the 20 amp fuse to the ...
Laser Stays On When System Shuts Off
Possible Cause#1 Loose wiring Solution Set#1 Check all wiring from compressor relay to launcher harness Possible Cause#2 Faulty crimp Solution Set#2 Remove crimps from compressor pull down Possible Cause#3 Bad computer box Solution Set#3 Replace ...