No Fire In Training Mode, No Launcher Elevation, CP and Laser On, Pressure Good

No Fire In Training Mode, No Launcher Elevation, CP and Laser On, Pressure Good

Possible Cause#1
Bad CB, PCM/PCR, or 12V connection to PCM/PCR

Solution Set#1
  1. Check for 12V going into PCM/PCR. If no 12V check fuse for PCM/PCR. If 12V present proceed to next step
  2. Check for 12V at orange wire on 4 Pin connector. If no 12V replace PCM/PCR. If 12V present proceed to next step
  3. Replace computer box and retest. If symptoms still show proceed to next step
  4. Internal fault in launcher, replace launcher 


    • Related Articles

    • Launcher Is Cycling Elevation Constantly

      Possible Cause#1 Possible bad PCM/PCR Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from PCR-including ...
    • Laser Aim Off

      Possible Cause#1 Lost memory in stepper  Solution Set#1 Put system in training mode and hard park it See StarChase V3.0 Launcher Park Reset Instructions Possible Cause#2 Laser needs re-aimed Solution Set#2 Follow laser aiming instructions See ...
    • No Compressor Or Launcher Control, Laser works

      Possible Cause#1 Defective PCM/PCR, fuse, wiring Solution Set#1 Check all power fuses Power up system put in training mode Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from ...
    • Launcher Fails To Arm; No Laser With System On

      Possible Cause#1 Control Panel Connections Solution Set#1 Verify Ignition power Verify 12V and ground connections Ensure Can-Bus Harness is connected ...
    • Intermittent Elevation

      Possible Cause#1 Console was  wired backwards/incorrectly Solution Set#1 Failed to hard park when in training mode (all connections flowed with the movement of the Launcher so nothing was preventing it from moving) ​System blew the 20 amp fuse to the ...