System Troubleshooting
Test
Hi
When System is armed, the arm button will blink for approx. 10 seconds, the ON and OFF button will turn off then on again, and the arming cycle resets
Possible Cause#1 Wires for the pressure switch shorting out the system and causing malfunction. Repair the wires Solution Set#1 Test the Compressor Check power fuses (25Amp) at battery. Ground single pin to compressor relay to ground to test ...
System Shutting Off Randomly After Armed To Fire
Possible Cause#1 Bad car battery leading to a low voltage results in failure to power StarChase system Solution Set#1 Verify connections Check Fuse Holders Ensure vehicle had enough time to charge battery post installation
When Pressing "ON" System Starts Powering Up Sequence But Cycle Stops Abruptly
Possible Cause#1 Bad car battery leading to a low voltage results in failure to power StarChase system Car alternator needs work/replaced Solution Set#1 Check to see if "ON" and "Down Arrow" buttons are illuminated
System Does Not Finish Power Up Sequence
Possible Cause#1 Bad car battery leading to a low voltage reading in system checks and failure to power StarChase system Solution Set#1 Car battery needs replaced
System Locked-No Elevation, No Laser
Possible Cause#1 No power to Computer Box Solution Set#1 Check fuse for PCM/PCR, replace if bad Check for movement of the launcher and/or compressor operation Check all connections and wiring Check power from PCM/PCR-including disconnecting grey ...
System Fails To Cycle To Fire
Possible Cause#1 Loose ignition wire Solution Set#1 Check ignition wiring Tighten or replace any loose or frayed wiring Possible Cause#2 Faulty Manifold Solution Set#2 Replace Pressure Manifold
System Not Working
Possible Cause#1 No power to control panel Solution Set#1 See control panel-no power Possible Cause#2 Defective PCM/PCR, fuse, wiring Solution Set#2 Check all power fuses Check all connections and wiring Check power from PCM/PCR-including ...
Systems Shuts Down When Armed
Possible Cause#1 System timed out Solution set#1 System will time out after 3 minutes of system on Fire system prior to 3 minute time out Turn on system and repeat arming cycle Possible Cause#2 System not getting enough power to operate Solution ...